Water supply system Nova Odesa
Technical
features
features
Type of
works
works
System
protection
protection
- Reliability category: Category II power supply powered by two independent 35 kV overhead lines.
- Design capacity: up to 3120 kW, taking into account the needs of pumping stations and redundancy.
- Equipment composition: 35 kV outdoor switchgear, 35/0.4 kV outdoor switchgear, power transformers, outdoor switchgear, cable lines.
- Design: power supply scheme, equipment selection, development of RPA and APCS, approval of documentation.
- Construction and installation works: construction of OHL-35 kV, installation of switchgear, laying of cables, connection to networks.
- Equipment manufacturing: manufacturing of control cabinets, SOC, ball screws, switchgear and switchgear at our own plant.
- Relay protection: MSP, short-circuit protection, phase failure, differential protection of transformers.
- Automation: implementation of automatic transfer switches, reclosers, remote and local control of system elements.
- Signaling and SCADA: monitoring of accidents, output of information to the dispatching system or automated process control system.